EFFECT OF COMBINED SOLUTION OF LACTIC AND ACETIC ACIDS ON THE MICROHARDNESS OF CERAM-X AND TETRIC N CERAM: AN EXPERIMENTAL STUDY

Authors

  • Sahibzada Ammar Ahmad Department of Science of Dental Materials, KCD, Peshawar.
  • Aiman Khan Department of Science of Dental Materials, KCD, Peshawar.
  • Nayab Amin Department of Science of Dental Materials, Sardar Begum Dental College, Peshawar
  • Atta Elahi Department of Science of Dental Materials, Peshawar Dental College, Peshawar.
  • Faiza Abdul Hakam Department of Prosthodontics, Khyber College of Dentistry, Peshawar, Pakistan.
  • Mohammad Saleem 1Department of Science of Dental Materials, Khyber College of Dentistry, Peshawar

DOI:

https://doi.org/10.33279/jkcd.v9i01.340

Abstract

Objective: 

Resin-based composite (RBC) restoration are susceptible to degradation by acids. Recent advances in RBC have incorporated organically modified ceramics into their formulations. The objective of the study was to document the effect of combined solution of lactic and acetic acids on the microhardness values of two ceramic based nanohybrid composites (CBNC).

Materials & Methods:

This experimental laboratory-based study was conducted on 40 specimens, 20 in each of the two CBNCs (Tetric N-Ceram and Ceram-X). The test specimens were made in a standard split mold having dimensions of10 mm diameter and 2 mm thickness. The specimen was cured and the baseline Vickers hardness number (VHN) was measured and the remaining microhardness assessment was done after the various immersion periods of 0, 2, 7 and 21 days. The data was analyzed in statistical program (SPSS version 25.0). Descriptive statistics along with repeated measures ANOVA was used for the comparison of microhardness. The level of p-value to be significant was set as 0.05.

Results:

The change in microhardness of both Tetric N-Ceram and Ceram-X after immersion in test media was statistically insignificant. It can be concluded that there was no effect of combined solution of acids on surface microhardness of both test materials.

Conclusion:

Within the limitations of this study it was concluded that the microhardness of Ceram-X and Tetric NCeram did not change significantly after different immersion periods in test immersion media. 

Downloads

Published

2019-03-31

How to Cite

Sahibzada Ammar Ahmad, Aiman Khan, Nayab Amin, Atta Elahi, Faiza Abdul Hakam, & Mohammad Saleem. (2019). EFFECT OF COMBINED SOLUTION OF LACTIC AND ACETIC ACIDS ON THE MICROHARDNESS OF CERAM-X AND TETRIC N CERAM: AN EXPERIMENTAL STUDY. JOURNAL OF KHYBER COLLEGE OF DENTISTRY, 9(01), 59–63. https://doi.org/10.33279/jkcd.v9i01.340