COMPARATIVE ASSESSMENT OF HARDNESS OF TWO NANO-HYBRID RESIN-BASED DENTAL COMPOSITES

Authors

  • Nayab Amin Department of Dental Materials, Rehman College of Dentistry
  • Usama Siddiqui Department of Dental Materials, Rehman College of Dentistry
  • Sahibzada Ammar Department of Dental Materials, Khyber College of Dentistry
  • Munazzah Ejaz Department of Dental Materials, Sardar Begum Dental College

DOI:

https://doi.org/10.33279/jkcd.v13i3.212

Keywords:

Resin based dental composites, hardness, hybrid

Abstract

Objectives: To compare the hardness of two nano-hybrid resin-based dental composites.

Materials and Methods: Two nano-hybrid composites i.e., Nexcomp by Meta Biomed, Korea, and Tetaric N Ceram by Ivoclar Vivadent, AG, Liechtenstein were selected, and hardness was evaluated according to ASTM E384-11e. T-test was used to statistically analyze the data.

Results: The mean hardness value (VHN) of Tetaric N Ceram (78.4±3.14) was high when compared with Nexcomp (50±4.12). The statistical analysis showed a signifi cant diff erence with  p-value of 0.00.

Conclusion: Both composites had adequate hardness values and dental practitioners may select  the material subject to the clinical situation and patient’s aff ordability.

Author Biography

Sahibzada Ammar, Department of Dental Materials, Khyber College of Dentistry

Assistant Professor

Downloads

Published

2023-09-30

How to Cite

Amin, N., Siddiqui, U., Ammar, S., & Ejaz, M. (2023). COMPARATIVE ASSESSMENT OF HARDNESS OF TWO NANO-HYBRID RESIN-BASED DENTAL COMPOSITES. JOURNAL OF KHYBER COLLEGE OF DENTISTRY, 13(3), 19–22. https://doi.org/10.33279/jkcd.v13i3.212